– True double-conversion online UPS
– Wide input voltage range (110-300 VAC)
– Input power factor correction 0.99
– Output power factor 0.8
– Converter mode available’

Sold By: Bitmart
  • Description
  • Additional information
  • Reviews (0)

Description

Mecer Winner Pro 3000VA 2U On-Line Rackmount UPS PF 0.8

 

Description:

– True double-conversion online UPS
– Wide input voltage range (110-300 VAC)
– Input power factor correction 0.99
– Output power factor 0.8
– Converter mode available
– ECO mode operation for energy saving (only available for 1-3KVA)
– Hot-swappable battery design only available for 1-3KVA
– Generator compatible
– Adjustable charging current via LCD or software (1A ~ 6A)
– Emergency power off function only available for 6K and up models

Specifications:

NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC. 

NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

Capacity: 3000 VA / 2400 W

Voltage Range:

– Low line transfer-160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp.<35°C)(based on load percentage 100%-80% / 80%-70%/ 70%-60%/ 60%-0
– Low line comback-175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp.<35°C)(based on load percentage 100%-80% / 80%-70% / 70-60% / 60%-0)
– High Line Transfer-300 vAC ± 5 %
– High line comback-290 VAC ± 5 %
– Frequency range-40Hz ~ 70 Hz
– Power factor-≧ 0.99 @ nominal voltage

 

Output:

– Output voltage-200/208/220/230/240 VAC
– AC Voltage Regulation(Batt. Mode)-± 1%
– Frequency Range (Synchronized Range)-47 ~ 53 Hz or 57 ~ 63 Hz
– Frequency Range (Batt. Mode)-50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
– Current Crest Ratio-3:1
– Harmonic Distortion-≦ 3 % THD (Linear Load), ≦ 6% THD (non-linear load)

 

– Transfer Time:
AC Mode to Batt. Mode-Zero
Inverter to Bypass-4 ms (Typical)

– Waveform (Batt. Mode)-Pure Sinewave

 

Efficiency:

– AC Mode-90%
– Battery Mode-88%

 

Battery:

– Battery Type-12V / 9Ah
– Numbers-6
– Typical Recharge Time-4 hours recover to 90% capacity
– Charging Current (max.)-N/A
– Charging Voltage-82.1 VDC ± 1%

 

Indicators:

– LCD Panel-UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

 

Alarm:

– Battery Mode-Sounding every 4 seconds
– Low Battery-Sounding every second
– Overload-Sounding twice every second
– Faul-Continuously sounding

 

Environment:

– Humidity-20-90 % RH @ 0- 40°C (non-condensing)
– Noise level-Less than 50dB @ 1 Meter

 

Management:

– Smart RS-232/USB-Supports Windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
– Optional SNMP-Power management from SNMP manager and web browser

 